ASSE (Plumbing) 1052-2004

$27.00

Performance Requirements for Hose Connection Backflow Preventers
standard by American Society of Sanitary Engineering, 2004

PDF FormatPDF FormatMulti-User-AccessMulti-User AccessPrintablePrintableOnline downloadOnline Download
Category:

Description

This standard establishes physical requirements, basic performance requirements and test procedures for hose connection backflow preventers. This device is designed to be installed on the discharge side of a hose threaded outlet on a potable water system. This two-check device protects against backflow, due to backsiphonage and low-head backpressure, under the high hazard conditions present at a hose threaded outlet. This device shall only be used on systems where sources of backpressure are not introduced. This device shall only be used on systems where the low-head backpressure does not exceed that generated by an elevated hose equal to or less than 3 m (10 ft.) in height. This device shall not be subjected to more than twelve (12) hours of continuous water pressure. A hose connection backflow preventer shall consist of two independent checks, force loaded or biased to a closed position, with an atmospheric vent located between the two check valves, which is force loaded or biased to an open position, and a means for attaching a hose.

Product Details

Published:
2004
Number of Pages:
28
File Size:
1 file , 580 KB
Note:
This product is unavailable in Ukraine, Russia, Belarus