UOP 742 – Sulfate in Catalyst by a Gravimetric Method
This method is for determining sulfate in alumina-base catalysts. The method is applicable to samples with sulfate levels of 0.03 mass-% or higher. Lower concentrations can be determined by UOP Method 320.